HGW4 series AC high voltage disconnector includes three single poles, each pole is of double column structure, which is mainly composed of base, post insulator and conductive part.

Overview

HGW4 series AC high voltage disconnector includes three single poles, each pole is of double column structure, which is mainly composed of base, post insulator and conductive part. Each pole has two insulating pillars, which are respectively installed on the bearing seats at both ends of the base and connected by cross connecting rods, which can rotate horizontally. The conductive knife switch is divided into two parts, which are respectively fixed on the post insulator, and the contact is in the middle of the two porcelain columns

Room.

When the operating mechanism acts, one post of the post insulator is driven to rotate by 90 degrees, and the other insulating post is also rotated by 90 degrees due to the transmission of the connecting rod, so the knife switch is opened and closed to the same side. In order to ensure the correct operation sequence between the disconnector and the grounding switch, a mechanical interlocking device is installed on the product or mechanism to ensure the sequential action of main opening and ground closing, ground opening and main closing.


Parameter

10kv-20kv


TypeRated voliage kvRated current ADynamic stability current kV(Peak)10s thermal stability currentkv(Peak)Weight (kg)
HGW4-10/400、630、125010400、630、125030、40、6515、20、2525
HGW4-10DW/400、630、125010400、630、125030、40、6515、20、2525
HGW4-15f400、630、125015400、630、125030、40、6515、20、2530
HGW4-15DW/400、630、125015400、630、125030、40、6515、20、2530
HGW4-20W/400、630、125020400、630、125030、40、6515、20、2535
HGW4-2ODW/400、630、125020400、630、125030、40、6515、20、2535


35kv-145kv

                                                  Type
Data
HGN4-40.5HOGH4-72.5HGR4-126HG24-126GHGN4-145

Rated voliage (kV)
40.572.5126126145
Rated current (A)630 1250
2000 2500
630 1250 2000
2500 4000
630 1250
2000 2500
630 12501250 2000 2500

Short tine withstand current(rms)
20 31.5
40(46)
031.5
40(46)
20 31.5
40(46)
20 31.520 31.5
40(46)
Peak vithstand current(peak)50 80
100(104)
50 80
100(104)
50 80
100(104)
50 6050 80
100(104)
Rated short-time pewer frequence
withstand voltaze(rms) kv

to each
85140185
(230)
185275

be tween breaks
110160210
(265)
210315
Lightning impulse withstand
roltage(peak)kv

to each
185325450
(550)
450650

between breaks
215375520
(630)
550750
Horizontal force of terninal e550
(750)
735-750100010001500
weight of single pole (kg)80200240300300